Home   |    My Account   |    Shopping Cart   |    Help & Support   |    About   |    Contact Us   
Document Number Title / Keyword
Search By Publisher
STANDARDS SEARCH: 


Shop By Industry
  - Boilers & Pressure Vessels
  - Electronics/Electrical/Telecom
  - Energy & Petrochem
  - Health & Safety
  - Quality Management
  - Water & Wastewater Quality
  - ECA eStore
  - AIA/NAS eStore
  - NEMA eStore
Featured Products
  - Alerts & Content Tools
  - ASTM Book of Standards
  - ASME Boiler & Pressure Vessels
  - National Board NBIC
  - Drawing and Drafting
  - Power & Process Piping
  - Telecommunications Standards
  - Smart Grid Meters
  - ISO 9000
  - The 9000 Store
Services
  - Abbreviations
  - Customer Service
  - Deposit Accounts
  - Free Catalogs
  - Free Newsletters
  - New/Revised Docs
  - Research Center
  - Standing Orders
  - Search Help
We Are Your One-Stop-Shop Standards Solution

Document Details

Return to search results
Prices displayed in United States Dollars (USD)

ICEA S-87-640 - Complete Document
Revision / Edition: 06    Chg:    Date: 09/13/06  
OPTICAL FIBER OUTSIDE PLANT COMMUNICATIONS CABLE 

Comments:   
Superseding Document:   
Page Count:  98 
In Stock:  Yes 
Hardcopy Price:   $ 179.00   Add to Cart 
Secure PDF Price What is a secure PDF?  $ 179.00   Add to Cart 

Document Abstract
Products

This Standard covers optical fiber communications cable intended for outdoor use and normally installed aerially, directly buried, or placed in underground ducts. Additional requirements for "figure-8" aerial self-supporting cables are included in Annex D, as appropriate. Materials, constructions, and performance requirements are included in the Standard, together with applicable test procedures. Refer to other published ICEA (ANSI/TIA) code product standards for information on fiber optic cable requirements for other applications:

• S-83-596: Optical fiber premises distribution cable (ANSI/TIA-472C000-B)

• S-101-696: Indoor-outdoor optical fiber drop cable (ANSI/TIA-472E000)

• S-110-717: Optical fiber drop cable (ANSI/TIA-472F000)

Applications Space

Products covered by this Standard are intended only for operation under conditions normally found in communications systems. These products normally convey communications signals (voice, video, and data) from point-to-point or point-to-multi-point, external to buildings. Products covered by this Standard may be factory terminated with connectors or splicing modules.

When a composite cable is required, the applicable metallic conductor requirements shall be as established by agreement between the end user and the cable manufacturer. The requirements of ANSI/ICEA S-84-608 should be considered when determining appropriate requirements.

Temperature Ranges

The normal temperature ranges for cables covered by this Standard are given in Table 1-1

For the purpose of this standard, very-low temperature applications, are defined as -50 °C (-58 °F) per 1.4.1.6, and are addressed in Annex C (Normative), which contains requirements for lower operating and storage temperatures than listed in Table 1.1.

Tensile Rating

The standard installation tensile rating for cables covered by this Standard is 2670 N (600 lbf). Higher tensile ratings are also acceptable for use. For applications where a lower tensile rating is approprite the standard lower tensile rating is 1330 N (300 lbf). In all cases, the residual load is defined as any load less than or equal to 30 percent of the installation tensile rating.

For self-supporting aerial applications there are additional considerations that need to be addressed to ensure that the cable design is appropriate for the self-supporting distance and environmental loading conditions. See 7.30 and Annex D for information on figure-8 self-supporting aerial cable requirements and considerations.

For aerial applications in which the optical cable is lashed to a separate messenger wire, the use of a cable designed for a standard tensile rating for installation by direct burial, trenching, or pulling into duct may be adequate.

Minimum Bend Diameter

The standard minimum bend diameters for cables covered by this Standard are:

Residual (Installed): 20 x Cable O.D.

Loaded Condition (During Installation): 40 x Cable O.D.

For very small cables, such as those installed in miniature ducts, manufacturers may specify a fixed cable minimum bend diameter (e.g., 300 mm) that is independent of the cable outer diameter (OD).

For cables not having a circular cross-section, bend diameter requirements are to be determined using the thickness (minor axis) as the cable and bending in the direction of the preferential bend.

View Previous Revisions View Referenced Standards

Customers who purchased ICEA S-87-640 have also purchased
  ANSI C12.1 : ELECTRIC METERS CODE FOR ELECTRICITY METERING
  ICEA P-45-482 : SHORT CIRCUIT PERFORMANCE OF METALLIC SHIELDS AND SHEATHS ON INSULATED CABLES
  NEMA WC 74 : 5-46 KV SHIELDED POWER CABLE FOR USE IN THE TRANSMISSION AND DISTRIBUTION OF ELECTRIC ENERGY
  TIA-942 : TELECOMMUNICATIONS INFRASTRUCTURE STANDARD FOR DATA CENTERS
  More Documents