Hello. Sign In   |    Help & Support   |    Contact Us   |   
Standards Store
  •  Shopping Cart  (0) 
      Your Shopping Cart is empty.
      If you already have an account, Sign In
      If you are new to IHS, Create New Account
SEARCH:
and/or  
ASME B16.34 (Complete Document)
Revision / Edition: 09    Chg: SUP    Date: 12/00/10   Abbreviations Definitions
Historical View current edition
VALVES-FLANGED, THREADED, AND WELDING END
Published By:ASME International (ASME)
Page Count:208
Secure PDF
$125.00 USD
  In Stock
Print :
$132.00 USD
  In Stock
Product Family
Amendments and Base Document
Current Edition
Referenced Items
There are no items in this referenced list
People Also Bought These
ASME B16.5
ASME B16.11
ASME B31.3
ASME B31.1
ASME BPVC-IX
More...
Related Products
There are no related products.
IHS Standards Expert
Description / Abstract Back to Top
General

This Standard applies to new construction and covers pressure–temperature ratings, dimensions, tolerances, materials, nondestructive examination requirements, testing, and marking for cast, forged, and fabricated flanged, threaded, and welding end and wafer or flangeless valves of steel, nickel-base alloys, and other alloys shown in Table 1. Wafer or flangeless valves, bolted or through-bolt types, that are installed between flanges or against a flange are treated as flanged-end valves. Alternative rules for NPS 2½ and smaller valves are given in Mandatory Appendix V.

Applicability

Standards and Specifications. Standards and specifications adopted by reference in this Standard and the names and addresses of the sponsoring organizations are shown in Mandatory Appendix VIII. It is not considered practical to refer to a specific edition of each of the standards and specifications in the individual clause references. Instead, the specific edition references are included in Mandatory Appendix VIII. A product made in conformance with a prior edition of reference standards and in all other respects conforming to this Standard shall be considered to be in conformance even though the edition reference may have been changed in a subsequent revision of this Standard.

Time of Purchase, Manufacture, or Installation.The pressure–temperature ratings included in this Standard are applicable, upon publication, to all valves covered within its scope that meet its requirements. For unused valves, valves that have been maintained in inventory, the manufacturer may certify conformance to this edition provided that it can be demonstrated that all requirements of this edition have been met. However, where such components were installed under the pressure–temperature ratings of an earlier edition of ASME B16.34, those ratings shall apply except as may be governed by an applicable Code or regulation.

User Accountability. This Standard cites duties and responsibilities that are to be assumed by the valve user in the areas of, for example, application, installation, system hydrostatic testing, operation, and material selection.

Quality Systems. Requirements relating to a valve manufacturer 's Quality System Program are described in Nonmandatory Appendix C.

Relevant Units. This Standard states valves in both metric and U.S. Customary units. These systems of units are to be regarded separately. The U.S. Customary units are shown in parentheses or are listed in separate tables. The values stated in each system are not exact equivalents; therefore it is required that each system of units be used independently of the other. Combining values from the two systems constitutes nonconformance with the Standard.

Selection of Valve Types and Material Service Conditions

Criteria for selection of valve types and materials suitable for particular fluid service are not within the scope of this Standard.

Convention

For the purpose of determining conformance with this Standard, the convention for fixing significant digits where limits, maximum and minimum values, are specified shall be ‘‘rounding off'' as defined in ASTM Practice E 29. This requires that an observed or calculated value shall be rounded off to the nearest unit in the last righthand digit used for expressing the limit. Decimal values and tolerances do not imply a particular method of measurement.

Denotation

Pressure Rating Designation. Class, followed by a dimensionless number, is the designation for pressure- temperature ratings. Standardized designations are as follows:

Class 150 300 600 900 1500 2500 4500

Class 400, an infrequently used flanged-end valve designation, is regarded as an intermediate class designation.

Size. NPS, followed by a dimensionless number, is the designation for nominal valve size. NPS is related to the reference nominal diameter, DN, used in international standards.
Additional Supplemental Documents

Prices subject to change without notice.
Help & Support
Home
Help & Support
Customer Care
Office Locations
Abbreviations Definitions
Products
Shop by Industry
Browse Publishers & Products
Featured Products
New Releases
Top Sellers
Tools & Services
Research Center
Alerts & Content Tools
Deposit Accounts
Standing Orders
Free Newsletters
Solutions
Individual Standards
Custom Online Collections
Online Corporate Solutions
 
Visit www.ihs.com
About IHS  |   Contact Us  |   Careers  |   Investors  |   Site Map  |   Privacy Policy  |   Terms of Use (c) 2014 IHS.