Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Self Extracting File Format
    • 👥
    • Immediate download
    • $173.00
    • Add to Cart
    • Printed Edition
    • Ships in 1-2 business days
    • $216.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Scope

Three-phase and single-phase ac synchronous and induction electric machines in ratings 0.18 kW (1/4 hp) and larger are covered in this guide. Primary emphasis is on the use of open or nonexplosionproof or nonflameproof enclosed machines in Zone 2 and Class I, Division 2 locations as covered in National Electrical Code(R) (NEC(R)) (NFPA 70-2020) and Canadian Electrical Code(R) (CE Code(R)) (CSA C22.1-2021 Safety Standard for Electrical Installations) as applicable. Surface temperature test methods and sine wave and non-sine wave applications are covered. Precautions against excessive surface temperatures and sparking are included. To help mitigate hot surface temperatures and sparking, this document provides guidance for selecting, operating, and maintaining machines in Zone 2 and Class I, Division 2 locations. This guide does not cover ac wound rotor machines and dc electric machines. Machines installed in locations other than Zone 2 and Class I, Division 2 as covered in NFPA 70-2020 or CSA C22.1-2021 are not covered in this guide. This document is not a specification and is not intended to be used as a specification for purchasing electric machines. The voltage breaks in this document are 1000 V and less, and over 1000 V.

Purpose

Existing codes and standards contain cautionary notes for open or nonexplosionproof or nonflameproof enclosed machines in Zone 2 and Class I, Division 2 locations as covered in the NEC and the CE Code. This guide documents industry experience and established practices and provides guidance for applying machines in these locations.

Abstract

Revision Standard - Active. Three-phase and single-phase ac synchronous and induction electric machines in ratings 0.18 kW (1/4 hp) and larger are covered in this guide. Primary emphasis is on the use of open or nonexplosionproof or nonflameproof enclosed machines in Zone 2 and Class I, Division 2 locations as covered in the NEC(R) (NFPA 70-2020) and CE Code(R) (CSA C22.1-2021) as applicable. Surface temperature test methods and sine wave and non-sine wave applications are covered. Precautions against excessive surface temperatures and sparking are included. To help mitigate hot surface temperatures and sparking, this document provides guidance for selecting, operating, and maintaining machines in Zone 2 and Class I, Division 2 locations. This guide does not cover ac wound rotor machines and dc electric machines. Machines installed in locations other than Zone 2 and Class I, Division 2 as covered in NFPA 70-2020 or CSA C22.1-2021 are not covered in this guide. This document is not a specification and is not intended to be used as a specification for purchasing electric machines. The voltage breaks in this document are 1000 V and less, and over 1000 V. (Additional documents for this standard can be downloaded at https://standards.ieee.org/content/dam/ieee-standards/standards/web/download/1349-2021_downloads.zip)
 

Document History

  1. IEEE 1349-2021

    👀 currently
    viewing


    IEEE Guide for the Application of Electric Machines in Zone 2 and Class I, Division 2 Hazardous (Classified) Locations

    • Most Recent
  2. IEEE 1349-2011


    IEEE Guide for Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations

    • Historical Version
  3. IEEE 1349-2001


    IEEE Guide for Application of Electric Motors in Class I, Division 2 Hazardous (Classified) Locations

    • Historical Version
 

Amendments, rulings, supplements, and errata

  1. IEEE 1349-2021/Cor 1-2022

    Free
    Download


    IEEE Guide for the Application of Electric Machines in Zone 2 and Class I, Division 2 Hazardous (Classified) Locations - Corrigendum 1