Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • PDF
    • 👥
    • PC37.41/D5c, Feb 2024 - UNAPPROVED DRAFT
    • $171.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Scope

This standard establishes design tests and specifications for high-voltage (above 1000 V) fuses and accessories for use on alternating current (ac) electrical distribution systems. Devices with rated maximum voltages to 170 kV are covered. The devices to which this standard applies are as follows: a) Expulsion fuses (including fuse cutouts); b) Current-limiting fuses; c) Items a) and b) used in fuse-enclosure packages; d) Fuse supports of the type intended for use with fuses and fuse disconnecting switches; e) Disconnecting devices (fuse disconnecting switches, disconnecting switches, and disconnecting cutouts) created by the use of a removable fuse unit or switch blade in a fuse support; f) Expulsion, current-limiting, and combination types of external capacitor fuses used with a capacitor unit, a group of units, or capacitor banks; g) Backup current-limiting fuses ("motor-starter fuses") used in conjunction with high-voltage motor starters; h) Fuse links when used exclusively with expulsion fuses and fuse disconnecting switches; i) Items a) through f) having integral load-break means; j) accessories including mounting brackets and switch sticks (switch hooks). This standard may also be used as a basis for testing other devices that are similar to the devices listed in the scope. In addition, the parts relating to expulsion fuses may, where applicable, be used for non-expulsion fuses in which the interruption process waits for a natural current zero to clear the circuit.

Purpose

This standard contains the specifications and minimum testing requirements for fuses and related devices. Such standardization is needed to help ensure uniform minimum product testing for, and consistent development and application of, devices within the document scope. Test areas covered are based on historical experience.

Abstract

Revision Standard - Active - Draft. Required procedures for performing design tests for high-voltage fuses, as well as for fuse disconnecting switches, are specified. These design tests, as appropriate to a particular device, include the following test types: dielectric, interrupting, radio-influence, temperature-rise, time-current, manual-operation, liquid-tightness, thermal-cycle, bolt-torque, withstand tests for motor circuit fuses, expulsion fuses using polymeric insulators, load-break, and short-time current.