1.1 This specification covers faced or unfaced, rigid cellular phenolic thermal insulation. Boards shall be faced or unfaced. Tubular forms and board cut from a block or bun covered by this standard shall be unfaced. It does not apply to field expanded cellular phenolic materials.

Note 1: If a facer or vapor retarder is to be used for the tubular form or board, then refer to Practice C921.

1.2 Materials covered by this specification are used as roof insulation; sheathing or rigid board for non-load bearing, building material applications; and pipe or board insulation cut from a block or bun for use between −40 and 257°F (−40 and 125°C). Type II and Type III materials with an appropriate vapor retarder covering on the warm surface are used to a lower temperature limit of −290°F (−180°C). (See 7.3.)

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 This specification covers closed cell rigid cellular phenolic thermal insulation manufactured using blowing agents with an ozone depletion potential of 0 (ODP 0).

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

For specific precautionary statements, see Section 16.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 

Document History

  1. ASTM C1126-19

    👀 currently
    viewing


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Most Recent
  2. ASTM C1126-18


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  3. ASTM C1126-15


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  4. ASTM C1126-14


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  5. ASTM C1126-13a


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  6. ASTM C1126-13


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  7. ASTM C1126-12a


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  8. ASTM C1126-12


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  9. ASTM C1126-11e1


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  10. ASTM C1126-11


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  11. ASTM C1126-10a


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  12. ASTM C1126-10


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  13. ASTM C1126-04


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  14. ASTM C1126-03


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  15. ASTM C1126-00


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version
  16. ASTM C1126-98


    Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

    • Historical Version