1.1 This specification covers the classification, composition, dimension, and physical properties of mineral fiber (rock, slag, or glass) semi-rigid and rigid board intended for the use as thermal insulation on surfaces operating at temperatures between 0°F (-18°C) and 1800°F (982°C). For specific applications, the actual temperature limits shall be agreed upon between the supplier and the purchaser.

1.2 For satisfactory performance, properly installed protective vapor retarder or barriers shall be used on below ambient temperature applications to reduce movement of water through or around the insulation towards the colder surface. Failure to use a vapor retarder or barrier can lead to insulation and system damage. Refer to Practice C921 to aid material selection. Although vapor retarder properties are not part of this specification, properties required in Specification C1136 are pertinent to applications or performance.

1.3 The orientation of the fibers within the boards is primarily parallel to the principal surface (face). This specification does not cover fabricated pipe and tank wrap insulation where the insulation has been cut and fabricated to provide a fiber orientation that is perpendicular to the surface (face).

1.4 This standard does not purport to provide the performance requirements of hourly-rated fire systems. Consult the manufacturer for the appropriate system.

1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 

Document History

  1. ASTM C612-14(2019)

    👀currently
    viewing


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Most Recent
  2. ASTM C612-14


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  3. ASTM C612-10


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  4. ASTM C612-09


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  5. ASTM C612-04e1


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  6. ASTM C612-04


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  7. ASTM C612-00a


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  8. ASTM C612-00


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version
  9. ASTM C612-83e1


    Standard Specification for Mineral Fiber Block and Board Thermal Insulation

    • Historical Version