Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $198.00
    • Add to Cart
    • Printed Edition + PDF
    • Immediate download
    • $226.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

Scope

This standard applies to surge protectors for application on multiconductor balanced or unbalanced information and communications technology (ICT) circuits and smart grid data circuits. These surge protectors are designed to limit voltage surges, current surges, or both. The surge protectors covered are generally multiple-component series or parallel combinations of linear or nonlinear elements, packaged or organized for the purpose of limiting voltage, current, or both. This standard describes the methods of testing and criteria (where appropriate) for the characteristics and ratings of surge protectors used in ICT circuits and smart grid data circuits. This standard is not intended to cover packaged single gas tube, air gap, varistor, avalanche junction, or self-restoring current limiter surgeprotective components (SPCs), which are covered by IEEE Std C62.31 [B20], IEEE Std C62.32 [B21], IEEE Std C62.33 [B22], IEEE Std C62.35 [B23], and IEEE Std C62.39 [B24], respectively. Specifically excluded from this standard are test methods for low-voltage power circuit applications. For protection of wire-line communication facilities under the specialized conditions found at power stations, consult IEEE Std 487 [B16] series of documents.

Abstract

Revision Standard - Active. Surge protectors for application on multiconductor balanced or unbalanced information and communications technology (ICT) circuits and smart grid data circuits are addressed in this standard. These surge protectors are designed to limit voltage surges, current surges, or both. The surge protectors covered are generally multiple-component series or parallel combinations of linear or nonlinear elements, packaged or organized for the purpose of limiting voltage, current, or both. The methods of testing and criteria (where appropriate) for the characteristics and ratings of surge protectors used in ICT circuits and smart grid data circuits are also described in this standard. Packaged single gas tube, air gap, varistor, or avalanche junction surge-protective components are not covered by this standard, but rather are covered by IEEE Std C62.31, IEEE Std C62.32, IEEE Std C62.33, and IEEE Std C62.35, respectively. Specifically excluded from this standard are test methods for low-voltage power circuit applications. For protection of wire-line communication facilities under the specialized conditions found at power stations, consult IEEE Std 487.
 

Document History

  1. IEEE C62.36-2016

    👀 currently
    viewing


    IEEE Standard Test Methods for Surge Protectors and Protective Circuits Used in Information and Communications Technology (ICT) Circuits, and Smart Grid Data Circuits

    • Most Recent
  2. IEEE C62.36-2014


    IEEE Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling Circuits

    • Historical Version
  3. IEEE C62.36-2000


    IEEE Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling Circuits

    • Historical Version
  4. IEEE C62.36-1994


    IEEE Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling Circuits

    • Historical Version
  5. IEEE C62.36-1991


    IEEE Standard Test Methods for Surge Protectors Used in Low-Voltage Data, Communications, and Signaling Circuits

    • Historical Version