Full Description

1.1 This practice covers the calculation and adjustment of the Langelier saturation index for the concentrate stream of a reverse osmosis (RO) device. This index is used to determine the need for calcium carbonate (CaCo3) scale control in the operation and design of RO installations. This practice is applicable for concentrate streams containing 10 to 10 000 mg/L of total dissolved solids. For concentrate containing over 10 000 mg/L, see Practice D4582.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 

Document History

  1. ASTM D3739-19

    👀 currently
    viewing


    Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis

    • Most Recent
  2. ASTM D3739-06(2010)


    Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis (Withdrawn 2019)

    • Historical Version
  3. ASTM D3739-06


    Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis

    • Historical Version
  4. ASTM D3739-05


    Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis

    • Historical Version
  5. ASTM D3739-94(2003)


    Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis

    • Historical Version
  6. ASTM D3739-94(1998)


    Standard Practice for Calculation and Adjustment of the Langelier Saturation Index for Reverse Osmosis