Language:
    • Available Formats
    • Options
    • Availability
    • Priced From ( in USD )
    • Printed Edition
    • Ships in 1-2 business days
    • $589.00
    • Add to Cart
    • Printed Edition + PDF
    • Immediate download
    • $845.00
    • Add to Cart

Customers Who Bought This Also Bought

 

About This Item

 

Full Description

This part of IEC 60255 specifies the minimum requirements for functional and performance evaluation of (longitudinal) differential protection designed for the detection of faults in ac motors, generators and transformers. This document also defines how to document and publish performance test results.

This document covers the differential protection function whose operating characteristic can be defined on a bias-differential plane. It includes specification of the protection function, measurement characteristics, compensation of energizing quantities, additional restraint or blocking methods (for overexcitation and magnetizing inrush), starting and time delay characteristics. This document also covers unrestrained differential protection functions traditionally combined with the restrained (biased) differential element to form a single differential relay.

This document defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions. The test methodologies for verifying performance characteristics and accuracy are also included in this document.

This document also includes current transformer requirements for the protection functions.

The differential protection functions covered by this document are as follows:
                                              IEEE/ANSI C37.2                                 IEC 61850-7-4 logical
                                              function numbers                               nodes
Transformer differential         87T                                                     PDIF
Motor differential                  87M                                                    PDIF
Generator differential            87G                                                     PDIF
Restricted earth fault (ground differential) 87N                               PDIF
Inrush restraint or inrush blocking                                                   PHAR
Overexcitation restraint or overexcitation blocking                         PHAR

This document does not specify the functional description of additional features often associated with biased differential relays such as current transformer (CT) supervision (CTS), switch onto fault (SOTF) and detection of geo-magnetically induced currents (GIC).

This document does not cover differential relays designed for bus bar protection (including high impedance differential protection and low impedance differential protection) or line protection. Additionally, this document does not explicitly cover generator incomplete longitudinal differential protection, generator split-phase transverse differential protection, self-balancing or magnetic balanced protection scheme, differential protection of phase-shifting transformers, directional restricted earth fault protection, railway transformers, convertor transformers and reactors. However, the principles covered by this document can be extended to provide guidance on these applications.

The general requirements for measuring relays and protection equipment are defined in IEC 60255-1.

 

Amendments, rulings, supplements, and errata

  1. IEC 60255-187-1 Ed. 1.0 b Cor.1:2023

    Free
    Download


    Corrigendum 1 to Measuring relays and protection equipment – Part 187-1: Functional requirements for differential protection – Restrained and unrestrained differential protection of motors, generators and transformers