About This Item

 

Full Description

This document specifies the required characteristics for single-pole, arc fault circuit breakers rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between – 40 °C to 85 °C at a maximum altitude of Z = 15 000 m. The thermal protection is temperature compensated and operates between – 55 °C and 125 °C.

These circuit breaker are operated by a push-pull type single pushbutton (actuator), with delayed action "trip-free" tripping.

They will continue to function up to the short-circuit current.

Cross References:
EN 4838-001
FED-STD-595B
MIL-I-81969/14
EN 3841-100
EN 3155-016
MIL-S-19500B
EN 6113
TR 6083
MIL-I-81969/1