About This Item

 

Full Description

CSA Preface 

This is the second edition of CSA C22.2 No. 60079-26, Explosive atmospheres — Part 26: Equipment with separation elements or combined levels of protection , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60079-26 (fourth edition, 2021-02). It supersedes the previous edition, published in 2016 as CAN/CSA-C22.2 No. 60079-26 (adopted IEC 60079-26:2014), Explosive atmospheres — Part 26: Equipment with Equipment Protection Level (EPL) Ga. It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CSA C22.2 No. 60079-26" throughout. This Standard is intended to be used in conjunction with CSA C22.2 No. 60079-0, Explosive atmospheres — Part 0: Equipment — General requirements. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard was reviewed for Canadian adoption by the CSA Integrated Committee on Hazardous Location Products, under the jurisdiction of the CSA Technical Committee on Industrial Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. 

Scope 

This part of IEC 60079 specifies requirements for construction, testing and marking for Ex Equipment that contains parts of the equipment with different Equipment Protection Levels (EPLs) and a separation element. This equipment is mounted across a boundary where different EPLs are required, for example between different gas hazardous areas, dust hazardous areas or gas hazardous areas adjacent to dust hazardous areas. EXAMPLE: Equipment installed in the wall of storage tanks located in Zone 1 and containing Zone 0 inside. Separation elements are considered for both electrical and non-electrical equipment. If mechanical energy can be transformed into a potential ignition source, additionally an ignition hazard assessment in accordance with ISO 80079-36 is performed and appropriate measures are undertaken. Suitable measures can be selected from ISO 80079-37 or IEC TS 60079-42. This document also specifies requirements for the combination of two Types of Protection, each with EPL Gb, to achieve EPL Ga. Examples are included in 4.2. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence.

 

Document History

  1. CAN/CSA C22.2 No. 60079-26:22

    👀 currently
    viewing


    Explosive atmospheres -- Part 26: Equipment with separation elements or combined levels of protection

    • Most Recent
  2. CAN/CSA C22.2 No. 60079-26:16 (R2021)


    Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga (Adopted IEC 60079-26:2014, third edition, 2014-10, with Canadian deviations)

    • Historical Version