1.1''This test method determines the quasi-static longitudinal tensile strength and elongation properties of fiber reinforced polymer matrix (FRP) composite bars commonly used as tensile elements in reinforced, prestressed, or post-tensioned concrete.

Note 1:''Additional procedures for determining tensile properties of polymer matrix composites may be found in Test Methods D3039/D3039M and D3916.

1.2''Linear elements used for reinforcing Portland cement concrete are referred to as bars, rebar, rods, or tendons, depending on the specific application. This test method is applicable to all such reinforcements within the limitations noted in the method. The test articles are referred to as bars in this test method. In general, bars have solid cross-sections and a regular pattern of surface undulations or a coating of bonded particles, or both, that promote mechanical interlock between the bar and concrete. The test method is also appropriate for use with linear segments cut from a grid. Specific details for preparing and testing of bars and grids are provided. In some cases, anchors may be necessary to prevent grip-induced damage to the ends of the bar or grid. Suggestions for a grouted type of anchor are provided in Appendix X1.

1.3''The strength values provided by this method are short-term static strengths that do not account for sustained static or fatigue loading. Additional material characterization may be required, especially for bars that are to be used under high levels of sustained or repeated loading.

1.4''Units'''The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.

1.4.1''Within the text, the inch-pound units are shown in brackets.

1.5''This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6''This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 

Document History

  1. ASTM D7205/D7205M-21

    👀 currently
    viewing


    Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars

    • Most Recent
  2. ASTM D7205/D7205M-06(2016)


    Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars

    • Historical Version
  3. ASTM D7205/D7205M-06(2011)


    Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars

    • Historical Version
  4. ASTM D7205/D7205M-06


    Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars

    • Historical Version