This specification covers single-cell precast reinforced concrete box sections cast monolithically and intended to be used for the construction of culverts and for the conveyance of storm water, industrial wastes, and sewage.

Note—This specification is primarily a manufacturing and purchasing specification. However, standard designs per the AASHTO LRFD Bridge Design Specifications are included and the criteria used to develop these designs are given in Appendix X1. The successful performance of this product depends on the proper selection of the box section, bedding, and backfill, and care that the installation conforms to the construction specifications. The owner of the precast reinforced concrete box sections specified herein is cautioned that the loading conditions and the field requirements must properly correlate with the box section specified and that inspection at the construction site must be provided.

 

Document History

  1. AASHTO M 259-23

    👀currently
    viewing


    Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers Designed According to the AASHTO LRFD Bridge Design Specifications (ASTM Designation: C1577-20)

    • Most Recent
  2. AASHTO M 259-22


    Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers Designed According to AASHTO LRFD (ASTM Designation: C789-95a)

    • Historical Version
  3. AASHTO M 259-20


    Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (ASTM Designation: C789-95a)

    • Historical Version
  4. AASHTO M 259-17


    Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (ASTM Designation: C789-95a)

    • Historical Version
  5. AASHTO M 259-11 (2015)


    Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (ASTM Designation: C789-95a)

    • Historical Version
  6. AASHTO M 259-98 (2002)


    Standard Specification for Precast Reinforced Concrete Box Sections for Culverts, Storm Drains, and Sewers (ASTM Designation: C789-95a)

    • Historical Version