Hello. Sign In
Standards Store

ANS 58.11

95th Edition, January 1, 1995

Complete Document

Design criteria for safe shutdown following selected design basis events in light water reactors

Includes all amendments and changes through Addendum , July 23, 2002


View Abstract
Product Details
Document History

Detail Summary

Not Active, See comments below

EN
Additional Comments:
W/D NO S/S
Format
Details
Price (USD)
Secure PDF
Single User
Call for Quote
Print
Backordered
Call for Quote
Add to Cart

Product Details:

  • Revision: 95th Edition, January 1, 1995
  • Published Date: July 23, 2002
  • Status: Not Active, See comments below
  • Document Language: English
  • Published By: American Nuclear Society (ANS)
  • Page Count: 19
  • ANSI Approved: Yes
  • DoD Adopted: No

Description / Abstract:

This standard provides design criteria for systems that perform the safety-related functions necessary to shut down a reactor and maintain it in a safe shutdown condition for selected design basis events; i.e., any design basis events that do not require operation of engineered safety features. For design basis events that require operation of engineered safety features, this standard can be selectively applied because of plant features specifically designed for these conditions. For systems that serve multiple functions, the design criteria associated with the most limiting function shall be applied.

The following safety-related functions are required for safe shutdown and are addressed in this standard:

(1) Reactor core reactivity control

(2) Reactor core heat removal

(3) Reactor coolant pressure boundary integrity provided by:

(a) Temperature control

(b) Pressure control, and

(c) Inventory control.