API RP 11S6

1st Edition, December 1, 1995

Complete Document

Recommended Practice for Testing of Electric Submersible Pump Cable Systems

Includes all amendments and changes through Reaffirmation Notice , October 2013


Detail Summary

Active, Most Current

EN
Additional Comments:
G11S61
Format
Details
Price (USD)
Secure PDF
Single User
$89.00
Print
In Stock
$89.00
PDF + Print
In Stock
$151.30 You save 15%
Add to Cart

People Also Bought These:

IPC-A-610
IPC/WHMA-A-620
ASCE 7-10
SAE AMS2750

Product Details:

  • Revision: 1st Edition, December 1, 1995
  • Published Date: October 2013
  • Status: Active, Most Current
  • Document Language: English
  • Published By: American Petroleum Institute (API)
  • Page Count: 27
  • ANSI Approved: No
  • DoD Adopted: No

Description / Abstract:

GENERAL

This recommended practice covers testing of Electric Sub-mersible pump Cable Systems. Cable testing, in general, can be broken into two basic categories: Factory Testing and Field Testing. This recommended practice only addresses procedures for Field Testing.

Factory Tests provide assurance that the finished product meets the anticipated performance criteria for the intended application. All the tests involved are used to detect gross cable defects in materials and workmanship. Typical tests on new cable include ac, dc, IR and Conductor Resistance, and are covered under such standards as IEEE 400, IEEE 1017, IEEE 1018, and IEEE 1019.

One consideration of any testing is that an electrical failure may not occur on a damaged cable during the actual test since testing is done under controlled conditions relative to oil well conditions. A more costly failure may then occur with the damaged cable downhole. Testing is simply an indicator of the insulation at that time. It is not a guarantee of future performance.

The test procedures and values outlined in this document are based upon accepted practices. Nevertheless, engineering judgment should be used to determine values and procedures applicable in specific situations.