Hello. Sign In
Standards Store

ASSE 1014

2005 Edition, January 1, 2005

Complete Document

Performance Requirements for Backflow Prevention Devices for Hand-Held Showers



View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$45.00
Print
In Stock
$45.00
Add to Cart

People Also Bought These:

NFPA 31
ANSI Z21.47/CSA 2.3
ANSI Z21.10.1
ANSI Z21.60/CSA 2.26

Product Details:


Description / Abstract:

Description

These devices provide backflow protection against backsiphonage and backpressure in handheld showers. These are separate devices or are integral with wall-mounted or deck-mounted tub fillers, flexible hoses, or components that are attached to shower arms.

General Requirements

The device(s) and associated components shall comply with the requirements of this standard and the applicable requirements of ASME A112.18.1 unless stated otherwise herein.

Minimum Working Pressure

The device shall be designed to withstand an inlet working pressure of a minimum of 125.0 psi (861.9 kPa).

Temperature

Temperature Range

The device shall be designed to function at temperatures from 40.0 °F to 120.0 °F (4.4 °C to 48.9 °C).

Maximum Temperature Spike

The device shall withstand temperature spikes up to 150 °F (65.6 °C).