ASTM D1056

2014 Edition, March 1, 2014

Complete Document

Standard Specification for Flexible Cellular Materials-Sponge or Expanded Rubber



View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$54.00
Print
In Stock
$54.00
PDF + Print
In Stock
$91.80 You save 15%
Add to Cart

People Also Bought These:

ASTM E18
ASTM A240/A240M
ASTM A370
ASTM D412

Product Details:

  • Revision: 2014 Edition, March 1, 2014
  • Published Date: March 1, 2014
  • Status: Active, Most Current
  • Document Language: English
  • Published By: ASTM International (ASTM)
  • Page Count: 15
  • ANSI Approved: No
  • DoD Adopted: Yes

Description / Abstract:

This specification covers flexible cellular rubber products known as sponge rubber and expanded rubber, but does not apply to latex foam rubber or ebonite cellular rubber. The base material for an open/closed cellular product may be made of synthetic, natural, or reclaimed rubber, or a mixture, and may contain other polymers or chemicals, or both, which may be modified by organic or inorganic additives. These elastomeric materials have properties similar to those of vulcanized rubber, namely (1) the ability to be converted from a thermoplastic to a thermosetting state by crosslinking (vulcanization) or (2) the substantial recovery of their original shapes when strained or elongated, or both.

Extruded or molded shapes of sizes too small for cutting standard test specimens are difficult to classify or test by these methods and will usually require special testing procedures.

In case of conflict between the provisions of this general specification and those of detailed specifications or test methods for a particular product, the latter shall take precedence. Reference to the test methods in this specification should specifically state the particular test or tests desired.

The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

The following safety hazards caveat pertains only to the test methods portions of this specification:This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

NOTE 1—ISO 6916-1 is similar to this specification.

*A Summary of Changes section appears at the end of this standard