1995 Edition, February 15, 1995

Complete Document

Standard Test Method for Water Vapor Content of Gaseous Fuels by Measurement of Dew-Point Temperature

Includes all amendments and changes through Reapproval Notice , 2012


View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$51.00
Print
In Stock
$51.00
PDF + Print
In Stock
$86.70 You save 15%
Add to Cart

People Also Bought These:

ASTM A370
ASTM E18
ASTM E415
ASTM B117

Product Details:

  • Revision: 1995 Edition, February 15, 1995
  • Published Date: January 2012
  • Status: Active, Most Current
  • Document Language: English
  • Published By: ASTM International (ASTM)
  • Page Count: 11
  • ANSI Approved: No
  • DoD Adopted: Yes

Description / Abstract:

This test method covers the determination of the water vapor content of gaseous fuels by measurement of the dewpoint temperature and the calculation therefrom of the water vapor content.

NOTE 1—Some gaseous fuels contain vapors of hydrocarbons or other components that easily condense into liquid and sometimes interfere with or mask the water dew point. When this occurs, it is sometimes very helpful to supplement the apparatus in Fig. 1 with an optical attachment that uniformly illuminates the dew–point mirror and also magnifies the condensate on the mirror. With this attachment it is possible, in some cases, to observe separate condensation points of water vapor, hydrocarbons, and glycolamines as well as ice points. However, if the dew point of the condensable hydrocarbons is higher than the water vapor dew point, when such hydrocarbons are present in large amounts, they may flood the mirror and obscure or wash off the water dew point. Best results in distinguishing multiple component dew points are obtained when they are not too closely spaced.

NOTE 2—Condensation of water vapor on the dew-point mirror may appear as liquid water at temperatures as low as 0 to −10°F (−18 to −23°C). At lower temperatures an ice point rather than a water dew point likely will be observed. The minimum dew point of any vapor that can be observed is limited by the mechanical parts of the equipment. Mirror temperatures as low as −150°F (−100°C) have been measured, using liquid nitrogen as the coolant with a thermocouple attached to the mirror, instead of a thermometer well.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.