Standard Test Methods for Chromium in Water



View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$48.00
Print
In Stock
$48.00
PDF + Print
In Stock
$81.60 You save 15%
Add to Cart

People Also Bought These:

VDA VOLUME 6 P3 (E)
STANDARD METHODS
ASTM E18
ASTM D445

Product Details:

  • Revision: 2017 Edition, June 1, 2017
  • Published Date: June 1, 2017
  • Status: Active, Most Current
  • Document Language: English
  • Published By: ASTM International (ASTM)
  • Page Count: 10
  • ANSI Approved: No
  • DoD Adopted: Yes

Description / Abstract:

These test methods cover the determination of hexavalent and total chromium in water. Section 34 on Quality Control pertains to these test methods. Three test methods are included as follows:

Test Method                                                             Concentration Range                                   Sections

A—Photometric Diphenylcarbohydrazide                        0.01 to 0.5 mg/L                                       7 – 15

B—Atomic Absorption, Direct                                        0.1 to 10 mg/L                                        16 – 24

C—Atomic Absorption, Graphite Furnace                         5 to 100 μg/L                                         25 – 33

Test Method A is a photometric method that measures dissolved hexavalent chromium only. Hexavalent chromium can also be determined by ion chromatography, see Test Method D5257. Test Methods B and C are atomic absorption methods that are generally applicable to the determination of dissolved or total recoverable chromium in water without regard to valence state. ICP-MS or ICP-AES may also be appropriate but at a higher instrument cost. See Test Methods D5673 and D1976.

Test Method A has been used successfully with reagent grade water Types I, II, and III, tap water, 10 % NaCl solution, treated water from a synthetic organic industrial plant that meets National Pollution Discharge Elimination System (NPDES) permit requirements, and EPA-extraction procedure leachate water, process water, lake water, effluent treatment, that is, lime neutralization and precipitation of spent pickle liquor and associated rinse water from stainless steel pickling. Test Method C has been used successfully with reagent water, stock scrubber water, lake water, filtered tap water, river water, well water, production plant water, and a condensate from a medium BTU coal gasification process. Matrices used, except for reagent water, are not available for Test Method B. It is the user’s responsibility to ensure the validity of these test methods for waters of untested matrices.

The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversion to inch-pound units that are provided for information only and are not considered standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 4.2, 20.3, and 20.8.1.

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

*A Summary of Changes section appears at the end of this standard