![]() ![]() ASTM D32572006 Edition, April 1, 2006Complete DocumentStandard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography
Includes all amendments and changes through Reapproval Notice , 2012
PDF
Single User
$48.00
Print
In Stock
Need it fast? Ask for rush delivery.
Most backordered items can be rushed in from the publisher in as little as 24 hours. Some rush fees may apply. Contact your nearest IHS Markit Office to request rush delivery of any backordered item.
$48.00
PDF + Print
In Stock
Need it fast? Ask for rush delivery.
Most backordered items can be rushed in from the publisher in as little as 24 hours. Some rush fees may apply. Contact your nearest IHS Markit Office to request rush delivery of any backordered item.
$81.60
You save 15%
Product Details:
![]() Description / Abstract:
These test methods cover the determination of ethylbenzene and
total eight-carbon (C8) and heavier aromatics in the
concentration range from 0.1 to 30 % in mineral spirits having a
distillation range from 149 to 210°C (300 to 410°F) as determined
by Test Method D86. The procedures permit the identification and
calculation of concentrations of aromatic components to 0.1 volume
%.
It is recognized by analytical chemists that a single column gas chromatography analysis of an unknown sample is risky. In such cases, multiple and different analytical techniques must be used for absolutely positive identification, for example, several different gas chromatography columns, gas chromatography/mass spectrometer, or gas chromatography/infrared, etc. In these test methods the material is known and is clearly defined. Oxygenated compounds, if present, may interfere and cause erroneous results. Such oxygenated compounds are not normally present in mineral spirits. Three test methods are covered as follows: Test Method A, measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene), and total aromatics by means of a single packed column gas chromatographic analysis. Test Method B, measurement of ethylbenzene content by means of a rapid packed column gas chromatographic analysis. Test Method C, measurement of ethylbenzene content, C8 plus higher aromatics (except ethylbenzene) and total aromatics by means of a capillary column gas chromatographic analysis. The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. For purposes of determining conformance of an observed or a calculated value using this test method to relevant specifications, test result(s) shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29. For hazard information and guidance, see the supplier's Material Safety Data Sheet. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. *A Summary of Changes section appears at the end of this standard ![]() |