Hello. Sign In
Standards Store

ASTM E1193

1997 Edition, October 10, 1997

Complete Document

Standard Guide for Conducting Daphnia magna Life-Cycle Toxicity Tests

Includes all amendments and changes through Reapproval Notice , 2012


View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$52.00
Print
In Stock
$52.00
PDF + Print
In Stock
$88.40 You save 15%
Add to Cart

People Also Bought These:

UL 94
NFPA 101
ASTM E119
ASTM E84

Product Details:

  • Revision: 1997 Edition, October 10, 1997
  • Published Date: January 2012
  • Status: Active, Most Current
  • Document Language: English
  • Published By: ASTM International (ASTM)
  • Page Count: 19
  • ANSI Approved: No
  • DoD Adopted: No

Description / Abstract:

This guide covers procedures for obtaining laboratory data concerning the adverse effects of a test material (added to dilution water, but not to food) on Daphnia magna Straus, 1820, during continuous exposure throughout a life-cycle using the renewal or flow-through techniques. These procedures also should be useful for conducting life-cycle toxicity tests with other invertebrate species, although modifications might be necessary. 

These procedures are applicable to most chemicals, either individually or in formulations, commercial products, or known mixtures. With appropriate modifications, these procedures can be used to conduct tests on temperature, dissolved oxygen, pH, and on such materials as aqueous effluents (also see Guide E1192), leachates, oils, particulate matter, sediments, and surface waters. The technique, (renewal or flow-through), will be selected based on the chemical characteristics of the test material such as high oxygen demand, volatility, susceptibility to transformation (biologically or chemically), or sorption to glass. 

Modification of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of standard test procedures. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information on new concepts and procedures for conducting life-cycle toxicity tests with D. magna.

The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 8.