Standard Test Method for Laboratory Measurements of Acoustical and Airflow Performance of Duct Liner Materials and Prefabricated Silencers

Includes all amendments and changes through Editorial Change 1, September 2015


View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$51.00
Print
In Stock
$51.00
PDF + Print
In Stock
$86.70 You save 15%
Add to Cart

People Also Bought These:

NFPA 130
SAE J200
NAS6703-6720
API 579-1

Product Details:

  • Revision: 2013 Edition, June 1, 2013
  • Published Date: September 2015
  • Status: Active, Most Current
  • Document Language: English
  • Published By: ASTM International (ASTM)
  • Page Count: 14
  • ANSI Approved: No
  • DoD Adopted: No

Description / Abstract:

This test method covers the laboratory testing of some of the acoustical properties of sound attenuating devices including duct liner materials, integral ducts, and in-duct absorptive straight and elbow silencers used in the ventilation systems of buildings. Procedures are described for the measurement of acoustical insertion loss, airflow generated noise, and pressure drop as a function of airflow. 

Excluded from the scope are reactive mufflers and those designed for uses other than in ventilation systems, such as automobile mufflers. 

This test method includes a provision for a simulated semi-reflective plenum to fit around thin-walled duct and silencer test specimens, since the acoustical environments around such thin-walled specimens can affect the measured insertion loss. 

This method tests the performance of the specimen in well-defined and controlled conditions. If the specimen is installed in the field in any different manner, the results may be different. This standard does not provide estimating procedures for determining the actual installed performance of the specimen under field conditions. 

The values stated in SI units are to be regarded as standard. The values in parentheses are provided for information only. 

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.