Hello. Sign In
Standards Store

ASTM F599

1995 Edition, January 1, 1995

Complete Document

Standard Specification for Poly(Vinylidene Chloride) (PVDC) Plastic-Lined Ferrous Metal Pipe and Fittings



View Abstract
Product Details
Document History

Detail Summary

Not Active, See comments below

EN
Additional Comments:
W/D NO S/S
Format
Details
Price (USD)
PDF
Single User
$57.00
Print
In Stock
$57.00
PDF + Print
In Stock
$96.90 You save 15%
Add to Cart

Product Details:

  • Revision: 1995 Edition, January 1, 1995
  • Published Date: September 10, 1995
  • Status: Not Active, See comments below
  • Document Language: English
  • Published By: ASTM International (ASTM)
  • Page Count: 4
  • ANSI Approved: Yes
  • DoD Adopted: No

Description / Abstract:



1. Scope

1.1 This specification covers factory-made poly(vinylidene chloride) (PVDC) plastic-lined ferrous metal pipe and fittings primarily intended for conveying corrosive liquids and gases. Requirements for materials, workmanship, dimensions, construction, working pressure and temperatures, test methods, and markings are included.

NOTE 1--This specification does not include products coated with PVDC nor does it define the suitability of PVDC-lined components in chemical environments.

1.2 The values given in parentheses are provided for information purposes only.

1.3 The ferrous piping products shall meet the requirements of the relevant specifications listed in 1.3.1, 1.3.2, and 1.3.3. Nominal sizes from 1 through 8 in. in 125, 150, and 300 psi ratings are covered.

NOTE 2--The PVDC sealing faces may prevent achievement of the full pressure rating of the ferrous housing. For pressure limitations, the manufacturer should be consulted.

1.3.1 For Ferrous Pipe:

1.3.2 For Ferrous Flanges:

1.3.3 For Ferrous Fittings:

1.4 The PVDC-lined pipe and fitting assemblies are limited to use from −18 to 79°C (0 to 175°F). For use below −18°C (0°F) consult the manufacturer. Use in specific aggressive environments may alter the above temperature range. The operating temperature range shall be established by mutual agreement between consumer and producer.

NOTE 3--Storage or handling below −7°C (20°F) of uninstalled 4, 6, and 8-in. lined pipe should be avoided.