SHORT CIRCUIT CHARACTERISTICS OF INSULATED CABLES

Includes all amendments and changes through Reaffirmation Notice , February 27, 2013


View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
Secure PDF
Single User
$89.00
Print
In Stock
$89.00
PDF + Print
In Stock
$124.60 You save 30%
Add to Cart

People Also Bought These:

ANSI/NEMA WC 74
ICEA P-45-482
ICEA S-108-720
NEMA WC 70

Referenced Items:

IEC 60949

Product Details:

  • Revision: 2007 Edition, February 27, 2013
  • Published Date: February 27, 2013
  • Status: Active, Most Current
  • Document Language: English
  • Published By: Insulated Cable Engineers Association (ICEA)
  • Page Count: 19
  • ANSI Approved: Yes
  • DoD Adopted: No

Description / Abstract:

Equations have been established for short circuit calculations for conductors made of copper or aluminum. The coverings and insulations, which determine the maximum allowable short circuit temperatures, are paper, varnished cloth and several thermoplastic and thermosetting materials presently appearing in ICEA standards. Temperature limits, considered safe, were established for the various covering and insulation materials.

The equations may be used to determine:

• The maximum short circuit permitted for a specific conductor and short circuit duration.

• The conductor size necessary to carry a specific short circuit current for a given duration.

• The maximum duration a specific conductor can carry a specific short circuit current.

An equation has been established for short circuit calculations with conductors of copper or aluminum. The insulations, which determine the maximum allowed short circuit temperatures, are described in the ICEA Standards. The equation is based on the heat content of the conductor material and the temperature limit of the insulation with the assumption that the time interval is so short that the heat developed during the short circuit is contained in the conductor. At the time this document was originally published there was no standard mathematical method available to calculate heat flow from the conductor through the insulation at the cessation of the short circuit load. It was necessary to enlist the aid and facilities of member laboratories and Massachusetts Institute of Technology to obtain in cooperation a solution to this problem so that safe temperature limits could be established for the various types of insulations. The solution is still a viable, conservative approach to the calculation of short circuit capacity.

Results are sufficiently conservative to neglect conductor skin effect except for very large conductors. Skin effect can be taken into account by dividing the right-hand member of the equations shown by the appropriate conductor ac/dc resistance ratio.