![]() IEC 60079-07th Edition, December 1, 2017Complete DocumentExplosive atmospheres – Part 0: Equipment – General requirements
PDF
Single User
$387.00
Print
In Stock
Need it fast? Ask for rush delivery.
Most backordered items can be rushed in from the publisher in as little as 24 hours. Some rush fees may apply. Contact your nearest IHS Markit Office to request rush delivery of any backordered item.
$387.00
People Also Bought These:![]() ISO/IEC 170253rd Edition, November 2017GENERAL REQUIREMENTS FOR THE COMPETENCE OF TESTING AND CALIBRATION LABORATORIES ![]() ISO 14229-12nd Edition, March 15, 2013ROAD VEHICLES - UNIFIED DIAGNOSTIC SERVICES (UDS) - PART 1: SPECIFICATION AND REQUIREMENTS Referenced Items:![]() IEC 60034-54.1 Edition, November 2006ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION ![]() IEC 60079-17th Edition, June 2014EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D" ![]() IEC 60079-1-11st Edition, July 2002ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 1-1: FLAMEPROOF ENCLOSURES "D" - METHOD OF TEST FOR ASCERTAINMENT OF MAXIMUM EXPERIMENTAL SAFE GAP ![]() IEC 60079-116th Edition, October 2014EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY "I" Product Details:
![]() Description / Abstract:
This part of IEC 60079 specifies the general requirements for construction, testing and marking of Ex Equipment and Ex Components intended for use in explosive atmospheres. The standard atmospheric conditions (relating to the explosion characteristics of the atmosphere) under which it may be assumed that Ex Equipment can be operated are:
• temperature –20 °C to +60 °C; • pressure 80 kPa (0,8 bar) to 110 kPa (1,1 bar); and • air with normal oxygen content, typically 21 % v/v. This part of IEC 60079 and other standards supplementing this standard specify additional test requirements for Ex Equipment operating outside the standard temperature range, but further additional consideration and additional testing may be required for Ex Equipment operating outside the standard atmospheric pressure range and standard oxygen content. Such additional testing may be particularly relevant with respect to Types of Protection that depend on quenching of a flame such as ‘flameproof enclosures “d”’ (IEC 60079-1) or limitation of energy, ‘intrinsic safety “i”’ (IEC 60079-11). NOTE 1 Although the standard atmospheric conditions above give a temperature range for the atmosphere of -20 °C to +60 °C, the normal ambient temperature range for the Ex Equipment is –20 °C to +40 °C, unless otherwise specified and marked. See 5.1.1. It is considered that –20 °C to +40 °C is appropriate for many items of Ex Equipment and that to manufacture all Ex Equipment to be suitable for a standard atmosphere upper ambient temperature of +60 °C would place unnecessary design constraints. NOTE 2 Requirements given in this standard result from an ignition hazard assessment made on equipment. The ignition sources taken into account are those found associated with this type of equipment, such as hot surfaces, electromagnetic radiation, mechanically generated sparks, mechanical impacts resulting in thermite reactions, electrical arcing and static electric discharge in normal industrial environments. NOTE 3 Where an explosive gas atmosphere and a combustible dust atmosphere are, or can be, present at the same time, the simultaneous presence of both often warrants additional protective measures. Additional guidance on the use of Ex Equipment in hybrid mixtures (mixture of a flammable gas or vapour with a combustible dust or combustible flyings) is given in IEC 60079-14. IEC 60079 does not specify requirements for safety, other than those directly related to the explosion risk. Ignition sources like adiabatic compression, shock waves, exothermic chemical reaction, selfignition of dust, naked flames and hot gases/liquids, are not addressed by this standard. NOTE 4 Although outside the scope of this standard, such equipment would typically be subjected to a hazard analysis that identifies and lists all of the potential sources of ignition by the equipment and the measures to be applied to prevent them becoming effective. See ISO/IEC 80079-36. This document is supplemented or modified by the following parts and technical specifications: This document, along with the additional parts of IEC 60079 mentioned above, is not applicable to the construction of • electromedical apparatus, • shot-firing exploders, • test devices for exploders, and • shot-firing circuits. ![]() |