IEC 60976

2nd Edition, October 1, 2007

Complete Document

Medical electrical equipment – Medical electron accelerators – Functional performance characteristics



View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
FR
Additional Comments:
BILINGUAL
Format
Details
Price (USD)
PDF
Single User
$375.00
Print
In Stock
$375.00
Add to Cart

People Also Bought These:

CSRS LEVEL 3
AENOR UNE-EN ISO 4042 ENG
IEC 60601-2-1
BS PD IEC/TR 60977

Product Details:

  • Revision: 2nd Edition, October 1, 2007
  • Published Date: October 2007
  • Status: Active, Most Current
  • Document Language: English, French
  • Published By: International Electrotechnical Commission (IEC)
  • Page Count: 172
  • ANSI Approved: No
  • DoD Adopted: No

Description / Abstract:

This International Standard applies to medical ELECTRON ACCELERATORS when used, for therapy purposes, in human medical practice.

This standard applies to medical ELECTRON ACCELERATORS which deliver a RADIATION BEAM of either X-RADIATION or ELECTRON RADIATION with NOMINAL ENERGIES in the range 1 MeV to 50 MeV at maximum ABSORBED DOSE RATES between 0,001 Gy s–1 and 1 Gy s–1 at 1 m from the RADIATION SOURCE and at NORMAL TREATMENT DISTANCES between 50 cm and 200 cm from the RADIATION SOURCE.

The present standard describes measurements and test procedures to be performed by the MANUFACTURER at the design and construction stage of a medical ELECTRON ACCELERATOR but does not specify ACCEPTANCE TESTS to be performed after installation at the purchaser's site. The accompanying report, IEC 60977, however, does suggest that many of the test procedures are appropriate for ACCEPTANCE TESTS.

The measurement conditions described in the present standard differ from those previously in use. This applies particularly to the PHANTOM position for measurements and the measurement of distances from the ISOCENTRE. These new conditions should be substituted for and not be added to previous methods.

This standard specifies test procedures for the determination and disclosure of functional performance characteristics, knowledge of which is deemed necessary for proper application and use of a medical ELECTRON ACCELERATOR and which are to be declared in the ACCOMPANYING DOCUMENTS together with the greatest deviation or variation to be expected under specific conditions in NORMAL USE. A format for presentation of functional performance values is given in Annex A.

It is recognized that inaccuracies in the test methods must be allowed for when assessing performance. However, it was not felt to be advisable to combine the errors into an overall performance tolerance but to keep them separate in the expectation that more accurate test methods will be evolved.

It is not intended that this standard should in any way inhibit the future development of new designs of equipment which may have operating modes and parameters different from those described herein, provided that such equipment achieves equivalent levels of performance for the TREATMENT of PATIENTS.

Except where otherwise stated this standard assumes that the medical ELECTRON ACCELERATORS have an ISOCENTRIC GANTRY. Where the equipment is non-isocentric, the description of performance and test methods may need to be suitably adapted.

NOTE A statement of compliance with this standard does not necessarily imply that these tests will be or have been applied as TYPE TESTS or as individual tests.