Scope

This document provides recommended maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently-installed, vented lead-acid storage batteries used in standby service. It also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to standby service stationary applications where a battery charger normally maintains the battery fully charged and provides the dc loads. The maintenance and testing programs described in this recommended practice represent "the best program" based on the information available at the time this document was developed. The user should evaluate these practices against their operating experience, operating conditions, manufacturer's recommendations, resources, and needs in developing a maintenance program for a given application. These maintenance and testing recommendations were developed without consideration of economics, availability of testing equipment and personnel, or relative importance of the application. Development of a maintenance and testing program for a specific application requires consideration of all issues, not just the technical issues considered in this document.

Purpose

The purpose of this recommended practice is to provide the user with information and recommendations concerning the maintenance, testing, and replacement of vented lead-acid batteries used in stationary applications.

Abstract

Revision Standard - Active. Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. Guidance to determine when batteries should be replaced is also provided. This recommended practice is applicable to standby service stationary applications where a charger maintains the battery fully charged and supplies the dc loads.
 

Document History

  1. IEEE 450-2020

    👀 currently
    viewing


    IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

    • Most Recent
  2. IEEE 450-2010


    IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

    • Historical Version
  3. IEEE 450-2002


    IEEE Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary Applications

    • Historical Version
  4. IEEE 450-1995


    IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

    • Historical Version
  5. IEEE/ANSI 450-1987


    IEEE Recommended Practice for Maintenance,Testing, and Replacement of Large Lead Batteries for Generating Stations and Substations

    • Historical Version