Scope

This standard covers drawout-type, indoor, medium-voltage ground and test (G&T) devices for use in drawout metal-clad switchgear rated 4.76 kV through 38 kV as described in IEEE Std C37.20.2(TM). Four G&T device types are generally supplied for temporary circuit maintenance procedures for insertion in place of the circuit breaker as follows: a) Simple manual devices b) Complex manual devices c) Simple electrical devices d) Complex electrical devices There may be more complicated G&T devices that may include current and/or voltage transformers, glow tubes, or other accessory components. These more complex devices are not covered by this standard. Due to their complexity, additional testing and interlocking are required, and manufacturers should be consulted for the availability and ratings of these types of devices.

Purpose

Although G&T devices have been used as accessory devices in metal-clad switchgear for decades, they were not addressed in the standards until IEEE Std C37.20.6™-1997 was approved. This is because they are specialized accessory devices, designed and tested in accordance with applicable sections of circuit breaker standards, and based on user-unique operational requirements. This revised standard complements IEEE Std C37.20.2 and addresses the more common G&T device types. This standard also clarifies that G&T devices are not required to have the interrupting and continuous current ratings of the circuit breakers they may temporarily replace for the purpose of grounding and testing medium-voltage circuits. It also recognizes that some devices may be offered with interrupting capabilities, and required tests for such devices are specified.

Abstract

Revision Standard - Active. Drawout-type ground and test devices for use in medium-voltage metal-clad switchgear rated 4.76 kV through 38 kV are covered. The description, design, and testing of these accessory devices that are inserted in place of drawout circuit breakers for the purpose of grounding and testing are also covered.
 

Document History

  1. IEEE C37.20.6-2015

    👀 currently
    viewing


    IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures

    • Most Recent
  2. IEEE C37.20.6-2007


    IEEE Standard for 4.76 kV to 38 kV Rated Ground and Test Devices Used in Enclosures

    • Historical Version
  3. IEEE C37.20.6-1997


    IEEE Standard for 4.76 kV to 38 kV Rated Grounding and Testing Devices Used in Enclosures

    • Historical Version