REACTION TO FIRE TESTS - ROOM CORNER TEST FOR WALL AND CEILING LINING PRODUCTS - PART 1: TEST METHOD FOR A SMALL ROOM CONFIGURATION



View Abstract
Product Details
Document History

Detail Summary

Superseded By: ISO 9705-1

Additional Comments:
NOW A PUBLISHED STD * SEE ISO 9705-1
Format
Details
Price (USD)
Print
In Stock
Call for Quote
Add to Cart

Product Details:


Description / Abstract:

This part of ISO 9705 specifies the test method to evaluate the reaction of wall and ceiling products to fire when installed at the surface of a small room and exposed directly to a specified ignition source. The test represents a fire scenario, which starts under well-ventilated conditions in a corner of a specified room with a single open doorway.

Tests performed in accordance with the method specified in this part of ISO 9705 provide data for the early stages of a fire from ignition up to flashover. The method does not evaluate the fire resistance of products. The method is not intended to evaluate floor coverings.

This method is not suitable for sandwich panel building systems, pipe insulation and fa├žades for which specific ISO standards (i.e. ISO 13784, ISO 20632 and ISO 13785, respectively) are available.