Hello. Sign In
Standards Store

SAE AS245

Revision C, November 1, 2014

Complete Document

(R) Water Solution Type Hand Fire Extinguisher



View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
$78.00
Print
In Stock
$78.00
Add to Cart

People Also Bought These:

SAE AMS4640
ANSI-ASC A14.3-2008
SAE AMS2759/9
ISA MC96.1

Product Details:

  • Revision: Revision C, November 1, 2014
  • Published Date: November 2014
  • Status: Active, Most Current
  • Document Language: English
  • Published By: SAE International (SAE)
  • Page Count: 8
  • ANSI Approved: No
  • DoD Adopted: No

Description / Abstract:

This specification covers the following types and classes of extinguishers:

Type I Stored pressure type

Category A - Operational Temperature range -40 to +140 °F (-40 to +60 °C)

Category B - Operational Temperature range +35 to +140 °F (+1.7 to +60 °C)

Type II Cartridge operated type

Category A - Operational Temperature range -40 to +140 °F (-40 to +60 °C)

Category B - Operational Temperature range +35 to +140 °F (+1.7 to +60 °C)

Purpose

The purpose of this AS is to specify minimum requirements for a water solution type hand fire extinguisher that shall be suitable for use on incipient fires which may occur in an airplane cabin interior. The type of fire for which these units are intended is one involving solid combustible materials such as paper, textiles and similar materials.

The goal of this standard is to provide fire extinguishers that have the physical attributes necessary to assure the airworthiness necessary for installation on aircraft type certificated under FAA/EASA regulations (14CFR/CS part 23, 25, 27, or 29, as applicable).