Performance of electrical appliances – Air conditioners and heat pumps Part 2: Energy labelling and minimum energy performance standards (MEPS) requirements



Detail Summary

Active, Most Current

EN
Additional Comments:
SAME AS SAA AS/NZS 3823.2
Format
Details
Price (USD)
PDF
Single User
$158.00
Print
In Stock
$193.00
Add to Cart

People Also Bought These:

AHAM HRF-1
IEC 60335-1
ASHRAE STD 16
AOAC METHODS

Product Details:

  • Revision: 2013 Edition, May 23, 2013
  • Published Date: May 23, 2013
  • Status: Active, Most Current
  • Document Language: English
  • Published By: Standards New Zealand (SNZ)
  • Page Count: 92
  • ANSI Approved: No
  • DoD Adopted: No

Description / Abstract:

This Standard specifies the energy labelling requirements for single-phase non-ducted air conditioners of the vapour compression type within the scope of AS/NZS 3823.1.1 and the MEPS requirements for single-phase and three-phase air conditioners of the vapour compression type up to a rated total cooling capacity of 65 kW that fall within the scope of AS/NZS 3823.1.1, AS/NZS 3823.1.2, AS/NZS 3823.1.3 or AS/NZS 3823.1.4.

Particular regulatory requirements for different categories of air conditioning equipment and validity dates are summarized in Appendix E of this Standard.

NOTE: Typical applicable products are shown in Appendix H.

This Standard does not specify electrical safety requirements.

This Standard specifies the following values for cooling and heating, as applicable:

(a) Rated power (input).

(b) Rated capacity (output).

(c) Energy Efficiency Ratio (EER) for cooling.

(d) Coefficient of Performance (COP) for heating.

(e) Annual Energy Efficiency Ratio (AEER) for cooling.

(f) Annual Coefficient of Performance (ACOP) for heating.

(g) Star Rating Index (SRI).

(h) Star rating.

(i) Some of the requirements for energy label validity.

(j) The performance criteria for energy labelling validity.

(k) Test report format.

(l) Printing requirements for air conditioner appliance energy labels.

(m) MEPS requirements for cooling and heating.

(n) Power quality (power factor).

NOTE: Terms that are defined in Clause 1.6 are shown in bold text.