UL 1069

7th Edition, February 19, 2015

Complete Document

UL Standard for Safety Hospital Signaling and Nurse Call Equipment

Includes all amendments and changes through Revision Page(s) , May 26, 2017


View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
Print
In Stock
$631.00
Add to Cart

People Also Bought These:

BS EN 50581
IPC/WHMA-A-620
ASQ Z1.4
BS EN 13718-1

Product Details:

  • Revision: 7th Edition, February 19, 2015
  • Published Date: May 26, 2017
  • Status: Active, Most Current
  • Document Language: English
  • Published By: UL (UL)
  • Page Count: 117
  • ANSI Approved: Yes
  • DoD Adopted: No

Description / Abstract:

The requirements in this standard cover the individual units and equipment that operate within the context of a fundamental hospital signaling nurse call system (NCS).

A fundamental NCS provides audible and visual communication between patients and staff in a health care facility and conforms to the minimum requirements established in the Health Care Failities Code, NFPA 99, and the National Eletrial Code, NFPA 70.

Accessory equipment or devices which are intended to be interfaced with a fundamental NCS to initiate routine calls or supplementary operation and which do not initiate emergency or code call signaling can be evaluated for compliance with applicable requirements described in this standard.

A minimal fundamental NCS performs the following operations:

a) Call Initiation – Activation of a staff or patient request for assistance via fixed or portable call initiation station,

b) Notification – Call annunciation (audible and visual) at a primary nurse control station,

c) Notification – Call-placed indicator (visual) on the call initiation station,

d) Notification – Call annunciation at a corridor lamp,

e) Notification – Zone annunciation (audible and visual) on a zone lamp, and

f) Call reset/cancellation.

A fundamental NCS may employ a wireless interface to perform fundamental operations or a supplementary operation such as notification at a redundant portable nurse’s station.

The units comprising a fundamental NCS covered by this standard are intended to be installed in patient care areas, staff areas, and support areas of a health care facility in accordance with the National Eletrial Code, NFPA 70, and the Health Care Failities Code, NFPA 99.

These requirements do not cover medical and dental equipment, line isolation monitors, X-ray equipment, electrically heated pads, therapeutic lamps, refrigerated oxygen therapy equipment, food warming cabinets and carts, equipment employed in inhalation anesthetizing or hazardous locations, office intercoms, or similar equipment and products covered by individual requirements.

These requirements do not cover equipment employed in an area of hyperbaric oxygenation, in which a patient is exposed during oxygen therapy to pressures greater than ambient atmosphere.