Hello. Sign In
Standards Store




Look Inside

UL 307A

9th Edition, October 8, 2018

Complete Document

UL Standard for Safety Liquid Fuel-Burning Heating Appliances for Manufactured Homes and Recreational Vehicles

Includes all amendments and changes through Revision Page(s) , October 8, 2018


View Abstract
Product Details
Document History

Detail Summary

Active, Most Current

EN
Format
Details
Price (USD)
PDF
Single User
Call for Quote
Print
In Stock
$998.00
Add to Cart

Product Details:

  • Revision: 9th Edition, October 8, 2018
  • Published Date: October 8, 2018
  • Status: Active, Most Current
  • Document Language: English
  • Published By: UL (UL)
  • Page Count: 131
  • ANSI Approved: Yes
  • DoD Adopted: No

Description / Abstract:

These requirements apply to the following types of liquid fuel-burning appliances intended for installation in manufactured homes and recreational vehicles, including travel trailers, camping trailers, truck campers, motor homes, and park trailers.

a) Direct vent system type heating appliances that provide for complete separation between the indoor atmosphere and combustion system, including the air supplied for combustion by inherent design of the furnace and its venting system.

b) Vented heating appliances other than of the direct vent system type that provide for separation between the indoor atmosphere and combustion system, including the air supplied for combustion by an installation method. Such appliances can be used only in manufactured homes, not in recreational vehicles.

Requirements for the installation and use of these appliances are included in the following standards:

a) For Manufactured Homes – The Department of Housing and Urban Development Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280, 1994.

b) For Recreational Vehicles – The National Fire Protection Association Standard for Fire Safety Criteria for Recreational Vehicles, NFPA 501C-1993.

An appliance constructed to burn liquid fuel or gas and a liquid fuel burning appliance constructed and designed so that it may be converted to burn gas by installation of a specific gas burner shall also comply with the applicable requirements in the Standard for Gas-Burning Heating Appliances For Manufactured Homes and Recreational Vehicles, UL 307B.

The term ″appliance″ as used in this standard refers to any heating appliance covered by this standard, such as a warm air central furnace, a wall furnace, a heating boiler, and a water heater.