1.1 This specification covers most forms of fiber-reinforced concrete manufactured in accordance with Specification C94/C94M or Specification C685/C685M as modified herein. It does not cover the placement, consolidation, curing, or protection of the fiber-reinforced concrete after delivery to the purchaser.
1.2 Certain sections of this specification are also applicable to fiber-reinforced concrete intended for shotcreting by the dry-mix or to zero-slump, and fiber-reinforced concrete used to manufacture precast elements. In these cases, the sections dealing with batching plant, mixing equipment, mixing and delivery, and measurement of workability and air content, are not applicable.
1.3 This specification does not cover thin-section glass fiber-reinforced concrete manufactured by the spray-up process that is under the jurisdiction of ASTM Subcommittee C27.40.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.5 If required results obtained from another standard are not reported in the same system of units as used by this standard, it is permitted to convert those results using the conversion factors found in the SI Quick Reference Guide.2
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.Warning-Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)3
1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
 

Document History

  1. ASTM C1116/C1116M-23

    👀 currently
    viewing


    Standard Specification for Fiber-Reinforced Concrete

    • Most Recent
  2. ASTM C1116/C1116M-10a(2015)


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  3. ASTM C1116/C1116M-10a


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  4. ASTM C1116/C1116M-10


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  5. ASTM C1116/C1116M-09


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  6. ASTM C1116/C1116M-08a


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  7. ASTM C1116/C1116M-08


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  8. ASTM C1116/C1116M-06


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  9. ASTM C1116/C116M-06


    Standard Specification for Fiber-Reinforced Concrete

    • Historical Version
  10. ASTM C1116-03


    Standard Specification for Fiber-Reinforced Concrete and Shotcrete

    • Historical Version
  11. ASTM C1116-02


    Standard Specification for Fiber-Reinforced Concrete and Shotcrete

    • Historical Version
  12. ASTM C1116-00


    Standard Specification for Fiber-Reinforced Concrete and Shotcrete

    • Historical Version