Hello. Sign In
Standards Store
ASTM C1107/C1107M 2014 Edition, July 1, 2014
Complete Document
Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
Includes all amendments and changes through Change/Amendment , July 1, 2014
Page Count:5
PDF :
$60.00 USD
In Stock
Print :
$60.00 USD
In Stock
ASTM BOS
IHS Standards Expert
This specification covers packaged dry, hydraulic cement grout (nonshrink) intended for use under applied load (such as to support a structure, a machine, and the like) where a change in height below initial placement height is to be avoided.

Grouts covered are composed of hydraulic cement, fine aggregate, and other ingredients. They require only the addition of mixing water for use.

The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

The following safety hazards caveat pertains only to the test method portion of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

*A Summary of Changes section appears at the end of this standard